Recycled Water Truck Program
• RW Use Permit - Updated June 2009.pdf
• RW Truck Program Guidelines - Updated June 2009.pdf
• Regional Water Quality Control Board Order 96-011 (MS Word Format)
Material Specs
NMWD Standards
• Standard Drawings (links to PDF’s): Description
| NO. | DESCRIPTION |
| 1 | TRENCH SECTION |
| 2 | VALVE RISER |
| 3 | CONCRETE THRUST BLOCKING |
| 4 | CONCRETE ANCHOR BLOCKS FOR VERTICAL BENDS |
| 5 | TYPICAL FIRE HYDRANT INSTALLATION |
| 6 | 2” BLOW-OFF ASSEMBLY |
| 7 | 6” BLOW-OFF ASSEMBLY |
| 8 | WATERLINE INSTALLATION THROUGH CASING |
| 9 | STANDARD FLANGE OUTLET WITH COLLAR PLATE REINFORCEMENT |
| 10 | TYPICAL STEEL WATERMAIN LOWERING |
| 11 | CABLE BONDING JUMPER INSTALLATION |
| 12 | SACRIFICIAL ANODE INSTALLATION |
| 13 | TELEMETRY CABLE CONDUIT AND PULL BOX |
| 14 | 4” STEEL MANIFOLD ASSEMBLY FOR MULTIPLE WATER SERVICE INSTALLATIONS |
| 15 | STANDARD WATER SERVICE INSTALLATION |
| 16 | DUAL 5/8” WATER METER INSTALLATION |
| 17 | FIRE SERVICE BELOW GRADE (DCDA) 2 1/2” THROUGH 8” |
| 18 | BELOW GRADE BACKFLOW PREVENTER ¾” AND 1” |
| 19 | ABOVE GRADE BACKFLOW PREVENTER ¾” THROUGH 2” |
| 20 | SIGN FOR HIGH PRESSURE WATERLINE |
| 21 | PROTECTION BARRIER FOR FIRE HYDRANT |
| 22 | VALVE MARKINGS |
| 23 | LEAKAGE CHART |
| 24 | SYMBOLS AND ABBREVIATIONS |
| 25 | APPROXIMATE DEPTH OF WATERMAIN FROM VALVE NUT |
| 26 | STANDARD AIR RELIEF VALVE INSTALLATION 1” TO 4” IN SIZE |
| 27 | SAMPLE STATION |
| 28 | TYPICAL PRESSURE REGULATING VALVE (PRIVATE RESIDENCE) |
NMWD Water Design and Construction Standards
Standard Specifications for Potable Water, Recycled Water and Sewer Facilities
| DIVISION | SECTION | DESCRIPTION |
| TABLE OF CONTENTS | ||
| 01 | GENERAL REQUIREMENTS | |
| 01000 | General Requirements | |
| 02 | SITE WORK | |
| 02200 | Earthwork | |
| 02202 | Slope Protection and Erosion Control | |
| 02203 | Trenching, Excavation, Backfilling & Compacting | |
| 02700 | Asphalt Concrete Paving | |
| 03 | CONCRETE (not used) | |
| 04 | MASONRY (not used) | |
| 05 | METALS (not used) | |
| 06 | WOOD AND PLASTICS (not used) | |
| 07 | THERMAL AND MOISTURE PROTECTION (not used) | |
| 08 | DOORS AND WINDOWS (not used) | |
| 09 | FINISHES (not used) | |
| 10 | SPECIALTIES (not used) | |
| 11 | EQUIPMENT (not used) | |
| 12 | FURNISHINGS (not used) | |
| 13 | SPECIAL CONSTRUCTION (not used) | |
| 14 | CONVEYING SYSTEMS (not used) | |
| 15 | MECHANICAL | |
| 15000 | General Piping System and Appurtenances | |
| 15041 | Disinfection of Piping | |
| 15043 | Sewer Leakage and Infiltration Testing | |
| 15044 | Hydrostatic Testing of Pressure Pipelines | |
| 15045 | Closed Circuit Television (CCTV) Inspections | |
| 15056 | Ductile-Iron Pipe and Fittings | |
| 15057 | Copper Tubing, Brass and Bronze Pipe Fittings | |
| 15061 | Cement-Mortar Lined and Coated Steel Pipe | |
| 15064 | Polyvinyl Chloride (PVC) Pressure Pipe | |
| 15065 | Polyvinyl Chloride (PVC) Gravity Sewer Pipe | |
| 15074 | Blowoff Assemblies | |
| 15099 | Process Valves and Miscellaneous Valves | |
| 15100 | Resilient Wedge Gate Valves (RWGV's) | |
| 15102 | Butterfly Valves (BFV's) | |
| 15108 | Air Release Valve, Air and Vacuum Valve, Combination Air Valve Assemblies and Manual Air Relief Service | |
| 15112 | Backflow Preventers | |
| 15151 | Recycled Water Facilities (Offsite) | |
| 15152 | Recycled Water Facitlities (Onsite) | |
| 15300 | Fire Hydrants | |
| 16 | ELECTRICAL (not used) |